|
Voltage class 36kV ideal for high voltage bus bar insulation
Heavy wall heat shrinkable tubing for protection and insulation of bus bar against accidents caused by electrified bare bus bar
Applications
 Bus bar insulation and protection
 In switchgears cabinets where space is limited and air spacing between bus bars need to be kept at minimal
Features/Benefits
 Reduce bus bar clearance requirement
 Give designer more freedom in designing switchgear cabinets when space is premium
 Protects against accidental flashover up to 36kV
 Protects against short circuit and electrical leakage caused small animals
 Protects against corrosion dirt and other contaminants that may cause accidental flashover
 Halogen Free
 Flame resistant with oxygen index higher than 27
 Available in continuous length roll form for convenient and economical installation
Temperature Rang
 Operating Temperature: -40~105¡æ
 Shrink Temperature: 125¡æ
Colour:red
Product Code Cross References
 Sumitomo: IRRAX sleeve SBI 350
Clearance Reduction Guide
| Bus bar Type |
Applicable Product |
Min. Clearance Required(mm) |
| Electrode toelectrode |
Electrode toground |
Electrode toelectrode |
Electrode toground |
| Round sectionalUp to 36 kV |
S1-35 |
160 |
220 |
200 |
270 |
| Rectangle sectionalUp to 36 kV |
S1-35 |
180 |
260 |
220 |
285 |
* The table above indicates the possible clearance reductions made by using S1 tubing. These clearances should not be adopted without testing. Sharp electrodes and usual geometries may require more clearance.
|
Test item |
Test standard |
Typical Data |
|
Density |
ASTM D2671 |
1.3~1.35 |
|
Heat shock 4hrs at 200¡æ |
ASTM D2671 |
No drop no flow |
|
Tensile strength
<4.0mm/0.18inch wall
>4.0mm/0.18inch wall |
ASTM D2671 |
>11Mpa
>10Mpa |
|
Ultimate Elongation |
ASTM D2671 |
>400% |
|
Accelerated Ageing 168hrs at 136¡æ
Tensile strength
Ultimate Elongation |
ASTM D2671 |
>10Mpa
>300% |
|
Low temperature flexibility 4hrs at -40¡æ |
ASTM D2671 |
No cracking |
|
Flammability |
ASTM D2863 |
OI>30 |
|
Volume resistivity |
ASTM D2671 |
>1014¦¸.cm |
|
Dielectric strength
2mm/0.08inch wall
2.5 mm/0.10inch wall
3 mm/0.12inch wall |
ASTM D2671 |
>20kV/mm
>17kV/mm
>15kV/mm |
|
Water absorption 336hrs at 23¡æ |
ASTM D570 |
<0.5% |
|
Resistance to selected fluids 168hrs at 23¡æ
Tensile strength
Ultimate Elongation |
IEC 60684-2 |
>8Mpa
>250% |
|
Copper corrosion 158¡æ for 168hrs |
IEC 60684-3 |
Pass |
|
Long term ageing 3000hrs at 120¡æ
Elongation at break |
IEC 60684-2 |
>175% |
|
Thermal endurance |
IEC 216 |
105¡æ |
|
Color fastness to light |
IEC 60684-3 |
Contrast between exposed and unexposed parts
The color no change |
|
Smoke index |
/ |
Less than 120 |
|
S1(n)-35 |
a + b
min. ~ max.
(mm) |
d
min. ~ max.
(mm) |
min. thickness for 36kV
shrink on the bus bar (mm) |
Standard Packing (m/roll) |
Standard Packing (roll/box) |
| ¦µ25/10 |
15 |
25 |
10 |
18 |
2.5 |
15 |
|
| ¦µ30/12 |
22 |
35 |
15 |
25 |
2.5 |
15 |
|
| ¦µ40/16 |
28 |
45 |
20 |
30 |
2.5 |
15 |
|
| ¦µ50/20 |
38 |
55 |
25 |
40 |
2.5 |
15 |
|
| ¦µ65/25(¦µ75/30) |
45 |
65 |
35 |
50 |
2.5 |
15 |
|
| ¦µ85/35(80/32) |
55 |
90 |
40 |
60 |
2.5 |
15 |
|
| ¦µ100/40 |
70 |
110 |
50 |
80 |
2.5 |
15 |
|
| ¦µ120/50 |
90 |
140 |
60 |
95 |
2.5 |
15 |
|
| ¦µ150/60 |
105 |
180 |
70 |
120 |
2.5 |
15 |
|
| ¦µ175/75 |
130 |
210 |
85 |
140 |
2.5 |
15 |
|
| ¦µ210/85 |
140 |
260 |
95 |
170 |
2.5 |
15 |
| |